Bionaire BCM6100-U Owner's Manual

Browse online or download Owner's Manual for Humidifiers Bionaire BCM6100-U. Bionaire BCM6100-U Owner's Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
cool moisture BEDROOM
humidifier
MODEL BCM6100
15.NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water reservoir and moving the unit.
16.This humidifier requires daily and weekly maintenance to
operate appropriately. Refer to daily and weekly cleaning
procedures. Use only cleaners and additives recom-
mended by the manufacturer.
17.NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner, or other household solvents to
clean any part of the humidifier.
18.Excessive humidity in a room can cause water conden-
sation on windows and some furniture. If this happens,
turn the humidifier OFF.
19.Do not use humidifier in an area where humidity level is
in excess of 50%. Use a hygrometer, available at your
local retailer or through the manufacturer, to measure the
humidity.
20.DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void your
warranty. The inside of the unit contains no user service-
able parts. All servicing should be performed by qualified
personnel only.
21.Never place housing under water flow or immerse in
liquids.
22.Do not plug in the cord with wet hands: electric shock
could result.
23.Do not pour water in any openings other than the water
reservoir.
24.To prevent damage to surfaces, do not place humidifier
under overhanging surfaces.
25.NEVER operate unit without water in the reservoir.
26.Do not move unit after it has been used until unit cools
completely.
27.Use both hands when carrying full reservoir of water.
PLEASE SAVE THESE
INSTRUCTIONS.
CONSUMER SAFETY INFORMATION
THIS PRODUCT IS EQUIPPED
WITH A POLARIZED AC (a plug
having one blade wider than the
other). This plug will fit into the
power outlet only one way. If the
plug does not fit fully into the
outlet, reverse the plug. If it still does not fit, contact qual-
ified personnel to install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY.
HUMIDIFIER SAFETY
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1.Read all instructions before using the appliance.
2.To avoid fire or shock hazard, plug the appliance directly
into a 120V AC electrical outlet.
3.Keep the cord out of heavy traffic areas. To avoid fire hazard,
NEVER put the cord under rugs or near heat registers.
4.DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. Locate your humidifier on
an inside wall near an electrical outlet. The humidifier
should be at least 4” away from the wall for best results.
5.NEVER place humidifier in an area where it is accessible
to children. NEVER use humidifier in a closed room,
particularly where a child may be sleeping, resting, or
playing (a closed room may result in excessive humidity).
6.WARNING: Do not attempt to refill humidifier without first
unplugging the unit from its electrical outlet. Failure to
heed this warning may cause personal injury. Be sure to
unplug the unit by pulling on the plug and not the cord.
7.Never place anything over moisture outlet when the unit
is running.
8.NEVER drop or insert any object into any openings
unless instructed in this manual.
9.DO NOT operate any appliance with a damaged cord or
plug, after the appliance malfunctions, or if it has been
dropped or damaged in any manner. Return appliance to
manufacturer for examination, electrical or mechanical
adjustment, or repair.
10.Use appliance only for intended household use as
described in this manual. Any other use not recom-
mended by the manufacturer may cause fire, electric shock,
or injury to persons. The use of attachments not recom-
mended or sold by the manufacturer may cause hazards.
11.DO NOT use outdoors.
12.Always place humidifier on a firm, flat, level surface. A water-
proof mat or pad is recommended for use under the humid-
ifier. NEVER place it on a rug or carpet, or on a finished floor
that may be damaged by exposure to water or moisture.
13.DO NOT allow the Moisture Outlet to directly face the wall.
Moisture could cause damage, particularly to wall paper.
14.Humidifier should be unplugged when not in use.
FILLING THE WATER TANK
1. Twist off the water tank cap located on the bottom of
the water reservoir by turning counter clockwise and fill
the water tank with cool, fresh water. Do not fill with
warm water as this may cause leaking.
2. After filling the water tank, replace the water tank cap
by firmly turning clockwise and then replace the water
reservoir on the base. The water reservoir will immedi-
ately begin to empty into the base.
FIRST USE ONLY
1. Put batteries into Remote. The “Room” humidity will be
displayed at all times. (Use 3 AAA Alkaline batteries
only, do not mix batteries)
2. Plug unit into outlet. The first time the unit is plugged in,
it will beep every two seconds until it is synced with the
remote. To sync unit with remote follow the below
steps:Unlock remote. (This must be done before
each use of the remote) To Unlock remote, hold
down the mode button for 2 seconds until the lock
symbol disappears on the screen. Once the remote
is unlocked, press the mode button again and the unit
will quickly beep 5 times telling the user the signal was
received. If you have more than one humidifier, DO
NOT SYNC more than 1 unit at once.
Battery Replacement: If the batteries are running low
on power, a low battery indicator will appear on the
remote. Low batteries will affect transmission distance
and the screen contrast. We recommend replacing bat-
teries immediately.
Remote Distance: The transmission distance for this
remote is approximately 30ft. Do not use farther than
30ft. from the appliance. Remote must be used in same
room as appliance.
Communication Safety Check: Every minute while in
Auto mode, the Galileo
®
Center communicates with the
base unit. If the Galileo
®
Center goes out of range and/or
has low batteries, the communication will stop, and after
8 minutes of non-communication the unit will shut off.
mode
Fig 2
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical rat-
ing of the extension cord must be equal to or greater than
the rating of the humidifier. Care must be taken to arrange
the extension cord so that it will not drape over the coun-
tertop or tabletop where it can be pulled on by children or
accidentally tripped over.
This device complies with Part15 of the FCC Rules.
Operation is subjected to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
Modifications not authorized by the manufacturer may
void user’s authority to operate this device.
HOW YOUR COOL MOISTURE HUMIDIFIER WORKS
Your Bionaire
®
Cool Moisture humidifier draws dry air
through the front air intake grill area. This air is then
passed through a moisture–laden wick filter which retains
the minerals and deposits. The resulting moist air is
directed back into the room from the top air grill.
Tip: This humidification system provides a cool, invisi-
ble moisture
output. It is normal not to see the mist.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched off and disconnected
from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4" away from the
wall. Do not place your
humidifier on furniture, a
floor location that will not
be damaged by mois-
ture is best.
3. Remove the water tank,
by holding the tank han-
dle and lifting straight
upwards.
4. Remove the filter door
by pulling the tab
straight out. Check to see
that the wick filter is
properly in place. Replace
the humidifier filter door.
Fig 1
A. Humidifier Tank
B. Carry Handle
C. Filter Monitor
D. Humidifier Housing
E. Filter Door
F. Humidifier Base
G. Control Panel
D
A
E
F
C
G
B
EXTENDED RUN TIME SETTING:
By setting you humidifier to a specific humidity level, you
are actually also extending the run time. Since the unit will
turn on and off to maintain the set humidity level, less
water will be used, so you will need to fill the unit less
than you would on manual setting.
UNIT OPERATION WITHOUT REMOTE
Your humidifier can be operated directly from the control
panel located on the top of the unit
A. Remote and Unit are OFF:
1. Press the Mode button on the unit the first
time.The “High” light illuminates and the unit runs
in “High” mode. The power light turns on.
2. Press the Mode button a second time to run in
“Med” mode.
3. Press the Mode button again to run in “Low” mode.
4. Press the Mode button again and the unit shuts off.
Note: The “auto” light only illuminates when the unit is
set to “auto” mode by the remote.
B. Remote is ON and Unit is ON:
1. Press the Mode button on the unit. The unit will
then switch “Modes”; either from “High” to “Med”,
“Med” to “Low”, or “Low” to “Off”. The unit’s
lights will reflect the change.
The Remote will display a different mode – the mode in
which it was left. If a button is pressed on the Remote,
the Remote’s signal will override the “Mode” on the unit
and the two will be back in sync.
TIMER FUNCTION:
Using Timer to Turn Unit Off
1) Hold mode button for 2 seconds to unlock remote.
2) Push + and - together.
2.1) "timer" turns on. 1 Hr appears on the screen.
3) Push + or - to adjust the number of hours the unit will
run before it automatically shuts itself off.
3.1) you can choose from; 1 to 8 hours
3.2) 1 through 8 will scroll in a continuous loop
4) After you have made your selection, the whole screen
flashes for 5 seconds after last button push of + or -
then goes back to previous mode
4.1) "timer" remains lit to show the timer function has
been set.
MANUAL OPERATION WITH REMOTE
1. Press Mode button on the remote. “High” illuminates on
remote screen indicating mode. The power light on the
unit will turn on. The unit turns on and operates in
“High” mode. The units “High” light will illuminate. In this
mode, the unit will continuously run at its high setting.
2. Press Mode button on remote a second time for “Med”
mode and once again for “Low” mode.
Note: While using the remote, the backlight function will
turn on when any button is pushed and will turn off after
10 seconds of non-use.
Note: Do not block ventilation openings on remote while in
use, this may affect the accuracy of the humidity reading.
HUMIDISTAT OPERATION WITH REMOTE
1. Press Mode button on remote until the remote screen
displays “Auto” and “High”. The “Set” humidity is dis-
played next to the “Room” humidity. The “Auto” light on
unit will illuminate. The unit will cycle on and off to main-
tain the “Set” humidity at high setting. NOTE: The
default room humidity is 45%. In this mode the unit will
run to maintain the “Set” humidity.
2. Press Mode button on remote again for “Med” and
“Auto”, and again for “Low” and “Auto”. The unit will
cycle on and off to maintain the “Set” humidity at the
designated setting.
3. To turn unit “Off”, press the Mode button and the LCD
will go blank (except for
the “Room” humidity dis-
play which is always dis-
played while batteries are
in the remote) and the unit
will shut off.
Note: It is normal for the
humidifier to cycle on and off
as it maintains the preset
humidity.
ADJUSTING SET HUMIDITY:
1. When in “Auto” mode, press the (+) or (-) buttons on
the remote. The “Set” number will increase or decrease
with each press. Hold the button down to scroll. The
minimum humidity is 35% and the maximum is 60%.
The unit scrolls one digit at a time in a continuous loop.
35%, 36%…, 59%, 60%, 35%, 36%….
Mode
High
Fig 3
Filter Monitor
Med
Low
Auto
REPLACING THE WICK FILTER
To replace the wick filter, follow the steps below.
Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water,
the greater the amount of minerals in the water, and the
more often you will need to change your wick filter. You
will be able to check the life of the filter on your humidifier
by checking the Filter Monitor located on the moisture
outlet. When the unit is not in operation, the Filter Monitor
will also read as OFF. When the unit is turned on, the
Filter Monitor needle will need 60 minutes to read the
current filter condition. If the needle reads change after
60 minutes, then filter replacement is needed. Regular fil-
ter replacement is necessary to ensure optimal humidifier
performance.
1. Turn the unit off and unplug the humidifier from the
electrical outlet.
2. Open the filter housing using the tab on the left side of
the filter door.
3. Discard the old wick filter and insert a new wick filter
into the hanging tabs.
4. Repeat “Operating Instructions” steps listed within. it
will take about 30 minutes for the humidifier to reach
maximum output.
You can obtain your filter model by calling
1-800-253-2764 in North America or by visiting your
nearest retailer or authorized service center. This
humidifier takes model WF6000 replacement filter.
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To get the most benefit from the
humidifier and avoid product misuse, follow all instruc-
tions carefully, specifically the operation, care and mainte-
nance guidelines. Please note that this is an electrical appli-
ance, and requires attention when in use.
In addition, if you do not follow the recommended care and
maintenance instructions, micro-organisms may be able to
grow in the water within the humidifier’s water tank.
5) At any time if you unlock the remote and push the
mode button to turn the unit off, the timer setting
will be erased and "timer" will disappear from the
remote.
6) To check how much time is remaining, press and hold
the + and – buttons simultaneously.
Using Timer to Turn Unit On
This function is meant for a person to pre-humidify a
room by setting the timer. For Example: It’s 8 am, and
you want to come home to a humidified room at 8 pm.
To accomplish this place the unit in the desired room and
set the timer to turn the unit on in 12 hours. Once the
timer is activated the unit will run for a preset time of 2
hours.
1) Hold mode button for 2 seconds to unlock remote.
2) DO NOT push mode again as this will turn unit on.
3) Push + and - together.
3.1) Unit remains off.
3.2) "timer" and "auto - high" turns on and flashes on
the remote, and 1 Hr appears on the screen.
4) Push + or - to adjust the number of hours that will pass
before it turns itself on.
4.1) you can choose from; 1to16 hours
4.2) 1 through 16 will scroll in a continuous loop
5) The whole screen flashes for 5 seconds after last but-
ton push of + or - then goes back to previous mode
5.1) The timer will turn the unit on and run for 2 hrs.
During the 2 hours, the digital humidistat will main
tain the room in auto – high at the default of 45%.
6) At any time if you unlock the remote and push the
mode button on the remote, the timer setting will
be erased and "timer" will disappear from the
screen.
7) To check how much time is remaining, press and hold
the + and – buttons simultaneously.
DAILY MAINTENANCE
1. Before cleaning, set the mode to the OFF position and
unplug the unit from the electrical outlet.
2. Lift off the water tank and the humidifier housing.
3. Carry the base and the water tank to the sink, remove
the filter, then drain and rinse the base and water tank
thoroughly to remove any sediment and dirt. Wipe
clean and dry with a clean cloth or paper towel.
4. Put the filter back in the unit, replace the humidifier
housing, then refill the water tank with cool tap water as
instructed under “Filling the Water Tank”.
5. If moisture forms on the walls or windows, turn off the
humidifier.
WEEKLY MAINTENANCE
Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one 8-oz
cup of undiluted white vinegar, or use Clean-Away
TM
by
Bionaire
®
. Let solution stand 20 minutes, cleaning all
the interior surfaces with a soft brush. Dampen a cloth
with undiluted white vinegar and wipe out entire base to
remove scale.
3. Rinse with clean warm water to remove scale and the white
vinegar solution before beginning to disinfect the tank.
DISINFECT TANK:
1. Fill water tank with 1 teaspoon of chlorine bleach and 1
gallon of water.
2. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
3. Empty the reservoir after 20 minutes, and rinse well
with water until the bleach smell is gone. Dry with a
clean cloth or paper towel.
4. Check to see if it is time to change the wick filter.
5. Refill the water tank with cool water, replace the humidi-
fier housing and the water tank. Repeat Operating
Instructions.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more,
or at the end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the
“Weekly Maintenance” instructions.
2. Let the humidifier dry completely before storing. Do not
store with water inside the base or water tank.
3. Remove the tank cap. Do not store with the tank cap in
place.
4. Store in a cool dry location.
SERVICE INSTRUCTIONS
1. Do NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void the
Warranty. The inside of the unit contains no user serv-
iceable parts. All servicing should be performed by
qualified personnel only.
2. If you need to exchange the unit, please return it in its
original carton, with a sales receipt, to the store where
you purchased it. If you are returning the unit more than
30 days after the date of purchase, please see the
enclosed Warranty.
3. Should your humidifier require service, please call
1-800-253-2764 in North America for further assis-
tance.
4
. If you have any other questions or comments, feel
free to write to us or visit our website
www.bionaire.com
The Holmes Group, Inc.
Consumer Service Department
13052 Jurupa Avenue
Fontana, CA 92337
Trouble Shooting for your Cool Mist Humidifier
Tr
ouble
•Mist output minimal to
none.
•Water leaks from water
reservoir.
•Water Filter turns brown.
•Film on water reservoir.
•Water cloudy.
•Humidistat cycles on/off.
•Very tight reservoir cap.
Probable Cause
Filter has not
absorbed water.
Mineral buildup in base.
Humidistat is set too low.
Wick Filter needs
to be replaced.
Normal operation.
Rubber O-ring is missing
or improperly placed.
Ta nk Cap not
tight enough.
Your filter needs
to be changed.
In areas with hard water
your wick filter will need
to be changed frequently.
Mineral deposits cause
film on tank to build up.
Filter needs
to be replaced.
Using warm water
to refill water tank.
Humidifier is reacting
to room humidity level.
Over tightened.
Solution
Wait 15 minutes before
starting humidifier.
Regular cleaning of tray
after each use will help
keep the unit functioning
properly.
Set the humidistat to
high.
Replace your wick filter
(WF6000) by calling
1-800-253-2764, or visit
www.bionaire.com.
Mist is invisible.
Check to see if inlet or
outlet grills are blocked.
Remove tank
cap then replace
or reposition ring.
Tighten the
tank cap.
Replace your wick filter
(WF6000) by calling
1-800-253-2764, or visit
www.bionaire.com.
Use Clean Away
TM
Solution
(DMS216), to order call
1-800-253-2764, or visit
www.bionaire.com.
Replace your wick filter
(WF6000) by calling
1-800-253-2764, or visit
www.bionaire.com.
Refill using cool water.
Set the humidistat to a
higher or lower setting.
Add liquid soap or
petroleum jelly to cap
gasket to ease opening.
Filter: WF6000
Read instructions before operating. Retain for future reference.
Instruction Leaflet
INFO-LINE
If after having read this leaflet, you have any questions
or comments on your humidifier,
call 1-800-253-2764 in North America.
WARRANTY
The Manufacturer warrants to the original retail purchaser, for
TWO (2) YEARS from the date of original purchase, either to
repair or replace at its option, without charge (parts and
labor), any supplied or manufactured part of this humidifier
which, upon inspection by an authorized service center,
proves to have failed in normal use due to defects in material
or workmanship, or, at its option, to replace the unit.
Operation under conditions other than those recommend-
ed or at voltages other than the voltage indicated on the
unit, or any attempts by unauthorized personnel to service
the unit or modify it, will render the guarantee void.
The Manufacturer shall not be liable for any personal injury,
property damage or any incidental or consequential dam-
ages of any kind, resulting from defects, malfunctions, mis-
use, improper installation or alteration of the product.
THE MANUFACTURER EXPRESSLY DISCLAIMS ALL
RESPONSIBILITY FOR CONSEQUENTIAL
DAMAGES OR INCIDENTAL LOSSES CAUSED
BY USE OF THIS PRODUCT.
The provisions of this Warranty are in addition to, and not
a modification of, or subtraction from the statutory
warranties and other rights and remedies contained in
any applicable legislation and to the extent that any such
provision purports to disclaim, exclude or limit any such
statutory warranties or other rights or remedies, such pro-
visions shall be deemed to be amended to the extent
necessary to comply therewith.
FOR WARRANTY SERVICE, PLEASE CALL
1-800-253-2764 IN NORTH AMERICA.
A consumer service representative will help determine
which is the best procedure in order for your humidifier to
be repaired.
KEEP THIS NUMBER FOR FUTURE REFERENCE.
Bionaire
®
the Bionaire logo
®
, Galile
®
and Clean-Away™ are trademarks of
The Holmes Group, Inc.
Printed In China
Fig. 4
FREQUENTLY ASKED QUESTIONS
Question
What are the variables that
affect run time?
How do I remove film on
water tank?
How can I extend the run
time?
Answer
The estimated run time for this humidifier is based on aver
age room conditions. The actual run time of your humidifier
is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifer is placed.
Movement of occupants and the opening and closing of
doors in the room where the humidifier is placed.
Home furnishings in the room where the humidifer is placed.
See Daily Maintenance instructions. Regular cleaning is
recommended.
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity
level. The unit will turn on and off, which will extend the run
time.
Fill the tank all the way full, place it on the base, let the
water empty into the base until it stops bubbling, then refill
the tank full again. This ensures maximum water capacity
and will extend run time.
Fig. 5
BCM610005EFM1.qxd 5/23/05 9:23 Page 1
Page view 0
1 2

Summary of Contents

Page 1 - Instruction Leaflet

cool moisture BEDROOMhumidifier MODEL BCM610015.NEVER tilt, move, or attempt to empty unit while it isoperating. Shut off and unplug before removing

Page 2 - Guide d’Utilisation

humidificateur àbueefroide POUR CHAMBREÀcoucherMODÉLE BCM61009100030002973usage non recommandé par le fabricant peut causer desrisques d’incendie, de

Comments to this Manuals

No comments